hit counter script

Cisco MDS 9124 - Fabric Switch Reference page 1110

Cisco mds 9000 family command reference - cisco mds san-os release 3.0(1) through 3.3(1a) (ol-16217-01, april 2008)
Hide thumbs Also See for Cisco MDS 9124 - Fabric Switch:
Table of Contents

Advertisement

show fcdomain
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Table 22-1
Table 22-1
Field
Domain ID
WWN
Principal
Local
Virtual (IVR)
The following example displays the allowed domain ID lists.
switch# show fcdomain allowed vsan 1
Assigned or unallowed domain IDs: 1-96,100,111-239.
[Interoperability Mode 1] allowed domain IDs: 97-127.
[User] configured allowed domain IDs: 50-110.
The following example shows the status of CFS distribution for allowed domain ID lists.
switch# show fcdomain status
CFS distribution is enabled
The following example displays pending configuration changes.
switch# show fcdomain pending vsan 10
Pending Configured Allowed Domains
----------------------------------
VSAN 10
Assigned or unallowed domain IDs: 1-9,24,100,231-239.
[User] configured allowed domain IDs: 10-230.
The following example displays the differences between the pending configuration and the current
configuration.
switch# show fcdomain pending-diff vsan 10
Current Configured Allowed Domains
----------------------------------
VSAN 10
Assigned or unallowed domain IDs: 24,100.
[User] configured allowed domain IDs: 1-239.
Pending Configured Allowed Domains
----------------------------------
VSAN 10
Assigned or unallowed domain IDs: 1-9,24,100,231-239.
[User] configured allowed domain IDs: 10-230.
The following example displays the status of the distribution session.
switch# show fcdomain session-status vsan 1
Last Action: Distribution Enable
Cisco MDS 9000 Family Command Reference
22-78
describes the significant fields shown in the show fcdomain domain-list command output.
show fcdomain Field Descriptions
Description
Lists the domain IDs corresponding to the WWN.
Indicates the WWN of the switch (physical or virtual) that requested the
corresponding domain ID.
Indicates which row of the display lists the WWN and domain ID of the
principal switch in the VSAN.
Indicates which row of the display lists the WWN and domain ID of the
local switch (the switch where you entered the show fcdomain
domain-list command).
Indicates which row of the display lists the WWN of the virtual switch
used by the Inter-VSAN Routing (IVR) manager to obtain the domain
ID.
Chapter 22
Show Commands
OL-16217-01, Cisco MDS SAN-OS Release 3.x

Advertisement

Table of Contents
loading

Table of Contents