Chapter 9
Troubleshooting
Fabric modules are included with the Cisco Nexus 7009, 7010, and 7018 chassis but not with the Cisco
Note
Nexus 7004 chassis.
When you start up the switch or install a new fabric module, the STATUS LED on the module is amber
while the module initializes. When the module becomes operational, the STATUS LED becomes green.
If an overtemperature condition occurs, the STATUS LED flashes red.
For a listing of the fabric module LEDs and the conditions that they indicate, see
To troubleshoot a fabric module hardware problem, follow these steps until the problem is resolved:
Check if a STATUS LED is flashing red or is unlit on each fabric module.
Step 1
Check if the power supply units are providing power to the chassis components.
Step 2
Make sure that the fabric module is properly seated in the chassis as follows:
Step 3
a.
b.
c.
d.
e.
f.
g.
Contact TAC for assistance (see the
Step 4

Troubleshooting the I/O Modules

The following conditions indicate that there are problems with one or more I/O modules:
During initialization, the STATUS LED is amber while the I/O module powers up and performs
diagnostic tests. When the diagnostic tests are complete, the STATUS LED becomes green. If an
overtemperature condition occurs, the STATUS LED becomes amber. If the module is resetting, ejectors
are out, or if there is a major overtemperature condition, the LED flashes red.
For a listing of the I/O module LEDs and the conditions that they indicate, see
OL-23069-07
The FAB LED on the chassis is amber.
The STATUS LED on the fabric module is red.
For information on troubleshooting AC power supply units, see the
Supply Unit" section on page
For information on troubleshooting DC power supply units, see the
Supply Unit" section on page
Loosen the captive screws on the fabric module until they are no longer in the chassis.
Press the eject buttons on either end of the module and simultaneously rotate out both ejector levers
until the module is unseated from the midplane.
Place one hand on the module handle and pull the module part way out of the chassis.
Push the module back into the chassis until it is seated on the midplane.
Simultaneously rotate both ejector levers until they both touch the front of the module. This action
fully seats the module on the midplane.
Make sure that each of the captive screws on the module is aligned with its holes in the chassis.
Screw in each captive screw to the chassis and tighten to 8 in-lb (0.9 N·m).
The IOM LED on the chassis is amber.
The STATUS LED on an I/O module is red.
9-2.
9-3.
"Contacting Customer Service" section on page
Cisco Nexus 7000 Series Hardware Installation and Reference Guide

Troubleshooting the I/O Modules

Table D-5 on page
"Troubleshooting an AC Power
"Troubleshooting a DC Power
9-8).
Table D-3 on page
9-7
D-6.
D-4.