Chapter 2
Cisco IOS Commands for the Catalyst 4500 Series Switches
show diagnostic result module test 2
To display the results of the bootup packet memory test, use the show diagnostic result module test 2
command. The output indicates whether the test passed, failed, or was not run.
Syntax Description
N
detail
Defaults
Non-detailed results.
Command Modes
EXEC mode
Command History
Release
12.2(18)EW
Usage Guidelines
The detail keyword is intended for use by Cisco support personnel when analyzing failures.
Examples
This example shows how to display the results of the bootup packet memory tests:
Switch# show diagnostic result module 1 test 2
Test results: (. = Pass, F = Fail, U = Untested)
This example shows how to display detailed results from the bootup packet memory tests:
Switch# show diagnostic result module 2 test 2 detail
Test results: (. = Pass, F = Fail, U = Untested)
___________________________________________________________________________
packet buffers on free list: 64557 bad: 0 used for ongoing tests: 979
OL-27596 -01
show diagnostic result module N test 2 [detail]
Modification
This command was introduced on the Catalyst 4500 series switch.
2) packet-memory-bootup ------------> .
2) packet-memory-bootup ------------> .
Error code ------------------> 0 (DIAG_SUCCESS)
Total run count -------------> 0
Last test execution time ----> n/a
First test failure time -----> n/a
Last test failure time ------> n/a
Last test pass time ---------> n/a
Total failure count ---------> 0
Consecutive failure count ---> 0
Catalyst 4500 Series Switch Cisco IOS Command Reference—Release IOS XE 3.4.0SG and IOS 15.1(2)SG)
Specifies the module number.
(Optional) Specifies the display of detailed information for analysis.
show diagnostic result module test 2
2-675