Table A-1
Environmental Ranges
Operating temperature
Storage temperature
Relative humidity
Operating altitude
Storage altitude
Power Requirements
AC input voltage
DC input voltages for
RPS 675
Power consumption
Power rating
Physical Dimensions
Weight
Dimensions (H x W x D) 1.73 x 17.5 x 12.8 in. (4.4 x 44.5 x 32.6 cm)
Table A-2
Environmental Ranges
Operating temperature
Storage temperature
Relative humidity
Operating altitude
Storage altitude
Power Requirements
DC input voltage
Power consumption
Physical Dimensions
Weight
Dimensions (H x W x D) 1.73 x 17.5 x 12.8 in. (4.4 x 44.5 x 32.6 cm)
Catalyst 3750 Switch Hardware Installation Guide
A-2
Specifications for the Catalyst 3750G-12S Switch
32 to 113°F (0 to 45°C)
–13 to 158°F (–25 to 70°C)
10 to 85% (noncondensing)
Up to 10,000 ft (3049 m)
Up to 15,000 ft (4573 m)
100 to 240 VAC (autoranging)
0.6 to 1.2 A, 50 to 60 Hz
+ 12 V
@13 A
120 W, 409 BTUs per hour
0.120 kVA
10 lb (4.6 kg)
Specifications for the Catalyst 3750G-12S-SD Switch
32 to 113°F (0 to 45°C)
–13 to 158°F (–25 to 70°C)
10 to 85% (noncondensing)
Up to 10,000 ft (3049 m)
Up to 15,000 ft (4573 m)
–36 to –72 VDC
3 to 1.5 A
94 W, 321 BTUs per hour
10 lb (4.6 kg)
Appendix A
Technical Specifications
OL-6336-06