9
263
Parameters
time-range-name
characters).
Default Configuration
No time range is defined
Command Mode
Global Configuration mode
User Guidelines
After entering to Time-range Configuration mode with this command, use the
absolute and periodic commands to actually configure the time-range. Multiple
periodic commands are allowed in a time range. Only one absolute command is
allowed.
If a time-range command has both absolute and periodic values specified, then
the periodic items are evaluated only after the absolute start time is reached, and
are not evaluated again after the absolute end time is reached.
All time specifications are interpreted as local time.
To ensure that the time range entries take effect at the desired times, the software
clock should be set by the user or by SNTP. If the software clock is not set by the
user or by SNTP, the time range is not activated.
Example
switchxxxxxx(config)#
switchxxxxxx(config-time-range)#
—Specifies the name for the time range. (Range: 1–32
time-range http-allowed
periodic mon 12:00 to wed 12:00