Chapter 28
Troubleshooting

Configuring OBFL

To enable OBFL, use the hw-module module [switch-number] logging onboard [message level level]
global configuration command. Use the message level level parameter to specify the severity of the
hardware-related messages that the switch generates and stores in the flash memory.
To copy the OBFL data to the local network or a specific file system, use the copy logging onboard
module stack-member destination privileged EXEC command.
We recommend that you do not disable OBFL and that you do not remove the data stored in the flash
Caution
memory.
To disable OBFL, use the no hw-module module [switch-number] logging onboard [message level]
global configuration command.
To clear all the OBFL data in the flash memory except for the uptime and CLI command information,
use the clear logging onboard privileged EXEC command.
You can enable OBFL by using the hw-module module logging onboard [message level level] global
configuration command.

Displaying OBFL Information

To display the OBFL information, use one or more of the privileged EXEC commands in
Table 28-3
Commands for Displaying OBFL Information
Command
show logging onboard [module
[switch-number]] clilog
show logging onboard [module
[switch-number]] environment
show logging onboard [module
[switch-number]] message
show logging onboard [module
[switch-number]] temperature
show logging onboard [module
[switch-number]] uptime
show logging onboard [module
[switch-number]] voltage
For more command options for the show logging onboard command and for examples of OBFL data,
see the command reference for this release.
OL-19808-01
Purpose
Displays the OBFL CLI commands that were entered on a standalone
switch or the specified stack members.
Display the UDI information for a standalone switch or the specified
stack members and for all the connected FRU devices: the PID, the VID,
and the serial number.
Display the hardware-related messages generated by a standalone switch
or the specified stack members.
Display the temperature of a standalone switch or the specified switch
stack members.
Display the time when a standalone switch or the specified stack members
start, the reason the standalone switch or specified stack members restart,
and the length of time that the standalone switch or specified stack
members have been running since they last restarted.
Display the system voltages of a standalone switch or the specified stack
members.
Catalyst 2360 Switch Software Configuration Guide
Using On-Board Failure Logging
Table
28-3:
28-23

Advertisement

Table of Contents
loading

Table of Contents