AC Power Consumption for the SAN192C-6 Director
Table 28 shows the typical AC power consumption for the SAN192C-6 Director.
AC Power Supply Requirements for Grid Redundancy
The minimum number of AC PSUs required to achieve grid redundancy on each of
the SAN c-type Directors differ. This number is irrespective of the optics
configured (See Table 5-20 ). Modifications made to the configurations may require
additional PSUs as per Table 29.
Note: The minimum number of AC PSUs required to achieve grid redundancy is
based on the maximum reserved power per chassis for any given configuration.
The actual power consumption will be lower.
106
SAN192C-6, SAN384C-6 and SAN768C-6 Installation, Service, and User Guide
Table 28. Consumption for SAN192C-6 Director
Number of Fabric
Speed/Module Type
Modules
32-G Fibre Channel
6
ports with SAN
c-type 48-port 32
Gbps Switching
Module
16-G Fibre Channel
3
ports with SAN
c-type 48-port
32-Gbps Switching
Module
Table 29. AC PSU Requirements for Grid Redundancy
Platform
SAN192C-6
SAN384C-6
Typical AC Power Consumption (Watts)
96 ports
1244
1052
Configurations
Up to 3 x SAN c-type 48 Port
32 Gbps Fibre Channel
Switching Modules
Any other supported module
or a combination of
supported modules:
v 48 Port 32 Gbps Fibre
Channel Switching
Module
v 24/10 port SAN Extension
Module
Up to 8 x SAN c-type 48 Port
32 Gbps Fibre Channel
Switching Modules
Any other supported module
or a combination of
supported modules:
v 48 Port 32 Gbps Fibre
Channel Switching
Module
v 24/10 port SAN Extension
Module
192 ports
1764
1572
Minimum PSUs Required
for Grid Redundancy
2
4
4
6