Safety instructions 9 Safety instructions What this chapter contains This chapter contains the safety instructions which you must obey when you install, operate and do maintenance to the drive. If you ignore the safety instructions, injury, death or damage can occur. Use of warnings Warnings tell you about conditions which can cause injury or death, or damage to the equipment.
10 Safety instructions 10 Safety instructions General safety in installation, start-up and maintenance These instructions are for all personnel that install the drive module and do maintenance work on it. WARNING! Obey these instructions. If you ignore them, injury or death, or damage to the equipment can occur.
Page 11
Safety instructions 11 • Before you adjust the drive operation limits, make sure that the motor and all driven equipment can operate throughout the set operation limits. • Before you activate the automatic fault reset or automatic restart functions of the drive control program, make sure that no dangerous situations can occur.
12 Safety instructions 12 Safety instructions Electrical safety in installation, start-up and maintenance Precautions before electrical work These warnings are for all personnel that do work on the drive, motor cable or motor. WARNING! Obey these instructions. If you ignore them, injury or death, or damage to the equipment can occur.
Safety instructions 13 Additional instructions and notes WARNING! Obey these instructions. If you ignore them, injury or death, or damage to the equipment can occur. • If you will install the drive on an IT (an ungrounded power system or a high- resistance-grounded [over 30 ohms] power system) or on a corner-grounded TN system, check the compatibility.
14 Safety instructions 14 Safety instructions Grounding These instructions are for all personnel who are responsible for the grounding of the drive. WARNING! Obey these instructions. If you ignore them, injury or death, or equipment malfunction can occur, and electromagnetic interference can increase.
Safety instructions 15 Additional instructions for permanent magnet motor drives Safety in installation, start-up and maintenance These are additional warnings concerning permanent magnet motor drives. The other safety instructions in this chapter are also valid. WARNING! Obey these instructions. If you ignore them, injury or death and equipment malfunction can occur.
16 Safety instructions 16 Safety instructions General safety in operation These instructions are for all personnel that operate the drive. WARNING! Obey these instructions. If you ignore them, injury or death, or damage to the equipment can occur. • Do not control the motor with the disconnector at the drive power supply; instead, use the control panel start and stop keys or commands through the I/O terminals of the drive.
Introduction to the supplement 17 Introduction to the supplement What this chapter contains This chapter describes the supplement. Applicability This supplement is applicable for these drive modules: • ACS880-01 with options +P940 and +P944 • ACS880-11 with option +P940 • ACS880-31 with option +P940. It is a supplement to these manuals: •...
18 Introduction to the supplement Purpose of the supplement The supplement tells you how to install the drive module into a cabinet. Related manuals Drive hardware manuals and guides Code (English) Cabinet installation supplement for ACS880 drive 3AUA0000145446 module frames R1 to R9 (options (+P940 and +P944) ACS880-01 hardware manual 3AUA0000078093...
Page 19
Introduction to the supplement 19 ACX-AP-x Assistant control panels user’s manual 3AUA0000085685 Drive firmware manuals and guides ACS880 primary control program firmware manual 3AUA0000085967 Quick start-up guide for ACS880 drives with primary 3AUA0000098062 control program Option manuals and guides Manuals and quick guides for I/O extension modules, fieldbus adapters, etc.
Hardware description 21 Hardware description What this chapter contains This chapter briefly describes the construction of the drive module options +P940 and +P944. For the operation principle and type code description, see the hardware manual. Product overview Drive with option +P940 is a drive module without front covers (ACS880-01 also without cable box) to be installed in a customer’s cabinet.
22 Hardware description Layout of option +P940 (IP20, UL Open Type) The components of the drive module are shown below (view of ACS880-01 frame R5, the other frames and drive module types are similar). Control panel Four attaching points at the back of the drive Heatsink Lifting holes...
Hardware description 23 Layout of option +P944 (IP20, UL Open Type) The components of the drive module are shown below (view of ACS880-01 frame R5, the other frames and drive module types are similar). Control panel Front cover Four fastening points at the back of the unit Heatsink Lifting holes...
Limitation of liability You must always plan and make the installation according to applicable local laws and regulations. ABB does not assume any liability whatsoever for any installation which breaches the local laws and/or other regulations. Installation position of the drive module The drive module must be installed in an upright position.
26 Guidelines for planning the cabinet installation Planning the layout of the cabinet Plan a spacious layout to ensure easy installation and maintenance. Sufficient cooling air flow, obligatory clearances, cables and cable support structures all require space. Place the control board(s) away from: •...
Page 27
Guidelines for planning the cabinet installation 27 Door closed Door open Air inlet Drive module with control unit and control panel Air outlet Input power cable including the protective ground conductor (PE) of the drive Contactor control switch and Motor cable including the protective emergency stop switch (connected to ground conductor the contactor control circuit inside the...
28 Guidelines for planning the cabinet installation Roof air flow viewed from top: Arranging the grounding inside the cabinet Arrange the grounding of the drive module by leaving the contact surfaces of the fastening points unpainted (bare metal-to-metal contact). The module frame will be grounded to the PE busbar of the cabinet via the fastening surfaces, screws and the cabinet frame.
• Always attach the drive module from its mounting points to the cabinet. For details, see the module installation instructions. WARNING! Do not attach the cabinet by electric welding. ABB does not assume any liability for damages caused by electric welding as the welding circuit can damage electronic circuits in the cabinet.
Page 30
• 360° high frequency grounding of the cable shields at the cable entries improves the EMC shielding of the cabinet. • ABB recommends 360° high frequency grounding of the motor cable shields at their entries. The grounding can be implemented by a knitted wire mesh screening as shown below.
Guidelines for planning the cabinet installation 31 • ABB recommends 360° high frequency grounding of the control cable shields at their entries. The shields can be grounded by means of conductive shielding cushions pressed against the cable shield from both directions as shown below.
Page 32
32 Guidelines for planning the cabinet installation • Equip the air inlets and outlets with gratings that guide the air flow protect against contact prevent water splashes from entering the cabinet. • The drawing below shows two typical cabinet cooling solutions. The air inlet is at the bottom of the cabinet, while the outlet is at the top, either on the upper part of the door or on the roof.
Guidelines for planning the cabinet installation 33 Minimum air inlet and outlet grating sizes Frame Minimum effective area of cabinet air Minimum effective area of cabinet air size inlet (cm outlet (cm IP22 IP54 IP22 IP54 1100 1250 1500 1100 1300 2000...
Page 34
34 Guidelines for planning the cabinet installation Main air flow in Main air flow out Air baffle plate Drive Air inlet filter Air outlet filter...
Guidelines for planning the cabinet installation 35 Installing drives above one another Make sure that the outlet cooling air flows away from the drive above. Air flow through the drive Air baffle Mounting plate that allows air through flow Minimum spacing between the drives max.+40 °C (+104 °F)
36 Guidelines for planning the cabinet installation Required free space The required free space at the top and bottom of the drive module is shown below. The free space is needed for making sure that sufficient cooling air flows through the module and the module cools correctly.
See section Routing the cables in the hardware manual. Installing ABB common mode filters (option +E208) Common mode filter kits are available from ABB. For ACS880-01 drive modules, without the cable entry box, hang the common mode filter ring on the cabinet structure.
Page 38
38 Guidelines for planning the cabinet installation...
Mechanical installation 39 Mechanical installation What this chapter contains This chapter gives guidelines for the mechanical installation of the drive module into a cabinet. Safety WARNING! For frame sizes R6 to R9: Use the lifting eyes of the drive when you lift the drive.
40 Mechanical installation Examining the installation site The drive modules can be installed tightly side by side. Make sure that the installation site agrees with these requirements: • The installation site has sufficient ventilation to prevent overheating of the drive. See section Losses, cooling data and noise in the hardware manual.
Mechanical installation 41 Unpacking and examining the delivery (frames R1 to R2) This illustration shows the layout of the transport package. Examine that all items are present and there are no signs of damage. Read the data on the type designation label of the drive to make sure that the drive is of the correct type.
42 Mechanical installation Unpacking and examining the delivery (ACS880-11 and ACS880-31 frame R3) The figure below shows the drive package with its contents. Examine that all items are present and there are no signs of damage. Read the data on the type designation label of the drive to make sure that the drive is of the correct type.
Mechanical installation 43 Unpacking and examining the delivery (ACS880-01 frames R3 to R5) This illustration shows the layout of the transport package. Examine that all items are present and there are no signs of damage. Read the data on the type designation label of the drive to make sure that the drive is of the correct type.
44 Mechanical installation Unpacking and examining the delivery (ACS880-01 frames R6 to R9) This illustration shows the layout of the transport package. Examine that all items are present and there are no signs of damage. Read the data on the type designation label of the drive to make sure that the drive is of the correct type.
Mechanical installation 45 Unpacking and examining the delivery (ACS880-11 and ACS880-31 frames R6 to R9) This illustration shows the layout of the transport package. Examine that all items are present and there are no signs of damage. Read the data on the type designation label of the drive to make sure that the drive is of the correct type.
46 Mechanical installation Installing the drive 1. See the dimensions in chapters Dimension drawings – ACS880-01 Dimension drawings – ACS880-11 and ACS880-31. Mark the locations for the four mounting holes. 2. Start the screws or bolts into the mounting holes. 3.
Electrical installation 47 Electrical installation What this chapter contains This chapter tells you how to install the power and control cables to the drive module. For other electrical installation instructions that concern the drive, see the hardware manual. Warnings WARNING! Only qualified electricians are allowed to carry out the work described in this chapter.
48 Electrical installation Checking the insulation of the assembly See the hardware manual. Attaching the residual voltage warning sticker See the hardware manual. Power cable connection diagram Drive module UDC+ T1/ T2/ T3/ R+ UDC- UDC- UDC+ (PE) (PE) 3 ~ M Use a separate grounding PE cable (1a) or a cable with a separate PE conductor (1b) if the conductivity of the shield does not meet the requirements for the PE conductor.
6. Attach the conductive sleeves to the cable shields with cable ties. 7. Seal the slot between the cable and mineral wool sheet (if used) with sealing compound (eg, CSD-F, ABB brand name DXXT-11, code 35080082). 8. Tie up the unused conductive sleeves with cable ties.
Page 50
50 Electrical installation 10. Connect the twisted shields of the power cables to the ground bar of the cabinet and the phase conductors to the drive module terminals. See Frame Section Page Installing the drive module shelves and connecting the cables –...
Electrical installation 51 Installing the drive module shelves and connecting the cables – ACS880-01 frames R1 and R2 1. Go through steps 1 to 9 in section Power cable connection procedure (IEC) page 49. 2. Attach the mechanical support self for the power cables to the drive module. 3.
54 Electrical installation Connecting the control cables – ACS880-01 frames R1 and R2 1. Strip the cable ends and cut to suitable length (note the extra length of the grounding conductors). 2. Ground the outer shields of all control cables 360 degrees at the cabinet entry. 3.
Electrical installation 55 Installing the drive module shelves and connecting the cables – ACS880-01 frame R3 1. Go through steps 1 to 9 in section Power cable connection procedure (IEC) page 49. 2. Attach the mechanical support self for the power cables to the drive module. 3.
58 Electrical installation Connecting the control cables – ACS880-01 frame R3 1. Strip the cable ends and cut to suitable length (note the extra length of the grounding conductors). 2. Ground the outer shields of all control cables 360 degrees at the cabinet entry. 3.
Electrical installation 59 Installing the drive module shelves and connecting the cables – ACS880-01 frames R4 and R5 1. Go through steps 1 to 9 in section Power cable connection procedure (IEC) page 49. 2. Install the control panel holder. PT4×12 1.2 N·m...
Page 60
60 Electrical installation 3. Remove the shroud on the power cable terminals by releasing the clips and lifting the shroud up from the sides with a screwdriver (a). Knock out holes in the shroud for the cables to be installed (b). 4.
Electrical installation 63 Connecting the control cables – ACS880-01 frames R4 and R5 1. Strip the cable ends and cut to suitable length (note the extra length of the grounding conductors). 2. Ground the outer shields of all control cables 360 degrees at the cabinet entry. 3.
64 Electrical installation Installing the drive module shelves and connecting the cables – ACS880-01 frames R6 to R9 1. Go through steps 1 to 9 in section Power cable connection procedure (IEC) page 49. 2. Remove the shroud on the power cable terminals by releasing the clips and lifting the shroud up from the sides with a screwdriver (a).
66 Electrical installation Connecting the control cables - ACS880-01 frames R6 to R9 1. Strip the cable ends and cut to suitable length (note the extra length of the grounding conductors). 2. Ground the outer shields of all control cables 360 degrees at the cabinet entry. 3.
Installation checklist 67 Installation checklist What this chapter contains This chapter contains a list for checking the mechanical and electrical installation of the drive module. Installation checklist Go through the checklist below together with another person. WARNING! Obey the safety instructions in chapter Safety instructions.
Page 68
68 Installation checklist Check that … Drive option modules and other components Type and number of option modules and other equipment is correct. Option modules and other equipment are not damaged. Option modules and terminals are labelled correctly. The placement of option modules and other equipment inside the cabinet and on the cabinet door is correct.
Page 69
Installation checklist 69 Check that … Fans that can be touched are shrouded. Live parts inside the doors are protected against direct contact to at least IP2x. Labels The type designation and instruction labels and warning are made according to the local regulations and placed correctly.
Page 70
70 Installation checklist Check that … The motor cable has been connected to the appropriate terminals, the phase order is right, and the terminals have been tightened. (Pull the conductors to check.) The brake resistor (if present) has been connected to the appropriate terminals, and the terminals have been tightened.
Technical data 71 Technical data What this chapter contains This chapter contains some technical data of the drive module. For other data, see the hardware manual.
Page 72
72 Technical data Dimensions, weights and free space requirements Note: ACS880-01 +P940 Frame IP20 UL Open Type Height Width Depth Weight Height Width Depth Weight 14.80 6.10 8.88 14.80 6.10 9.78 17.17 6.81 10.09 16.1 22.17 7.99 13.12 19.3 25.70 7.99 13.12 38.8...
Technical data 73 200 mm (7.87 in.) free space is required at top of the drive module. 300 mm (11.81 in.) free space is required at bottom of the drive module. Degree of protection IP20 (UL Open Type)
Dimension drawings – ACS880-01 75 Dimension drawings – ACS880-01 What this chapter contains This chapter contains dimension drawings of the ACS880-01 drive module.
Dimension drawings – ACS880-11 and ACS880-31 95 Dimension drawings – ACS880-11 and ACS880-31 What this chapter contains This chapter contains dimension drawings of the ACS880-11 and ACS880-31 drive modules.
98 Dimension drawings – ACS880-11 and ACS880-31 R8 – Option +P940 (IP20, UL Open Type)
Page 99
Address any inquiries about the product to your local ABB representative, quoting the type designation and serial number of the unit in question. A listing of ABB sales, support and service contacts can be found by navigating to abb.com/searchchannels. Product training For information on ABB product training, navigate to new.abb.com/service/training.