9.3
Dialog selection via NC
MMC command in HMI Operate
You can use MMC commands as described in the following:
1. Definition of MMC commands
The following is available in the standard systemconfiguration.ini file.
Combinations:
address:=MCYCLES --> command:=LM
address:=CYCLES --> command:=PICTURE_ON
This distinction is necessary in order to differentiate between measuring cycles and other
cycles. This means that:
– LM is always applicable for measuring cycles, PICTURE_ON, always for non-measuring
– It is not permissible that newly defined MMC commands are designated PICTURE_ON
2. "Run MyScreens" license
All the dialogs opened by "Run MyScreen", with the exception of measuring cycles, fall
under the "Run MyScreens" license, which means that without license, only a limited
number of dialogs can be used.
Example call with test.com (Run MyScreens):
g0 f50
MMC("CYCLES,PICTURE_ON,test.com,screen form1","A")
m0
MMC("CYCLES,PICTURE_OFF","N")
M30
SINUMERIK Integrate Run MyScreens
Programming Manual, 10/2015, 6FC5397-3DP40-5BA3
cycles
and LM
Dialog selection
9.3 Dialog selection via NC
197