hit counter script

Siemens SINUMERIK 828D Commissioning Manual page 1027

Hide thumbs Also See for SINUMERIK 828D:
Table of Contents

Advertisement

There are two types of CHANGE method, i.e., element-specific and global:
● The element-specific CHANGE method is executed if the value of a specified variable
changes. If a system or user variable is assigned to a variable, cyclic updating of the variable
value can be configured in a CHANGE method.
● The global CHANGE method is executed if the value of any variable changes and no
element-specific CHANGE method has been configured.
"Element-specific" programming
Syntax:
Description:
Parameters:
Example
DEF VAR1=(I//////"DB20.DBB1")
CHANGE(VAR1)
IF VAR1.Val <> 1
VAR1.st="Tool OK!"
ELSE
ENDIF
VAR2.Var=2
END_CHANGE
"Global" programming
Syntax:
Description:
Parameters:
SINUMERIK Integrate Run MyScreens
Programming Manual, 10/2015, 6FC5397-3DP40-5BA3
otto=1
VAR1.st="Attention: Error!"
otto=2
(Identifier)
CHANGE
...
END_CHANGE
Changes the value of a specific variable
Identifier
Name of the variable
; A system variable is assigned to Var1
; If the value of the system variable ≠ 1, the
short text of the variable states: Tool OK!
; If the value of the system variable = 1, the
short text of the variable states: Attention:
Error!
CHANGE()
...
END_CHANGE
Changes any variable value
- None -
Programming commands
6.2 Methods
97

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents

Save PDF