Electrical System Operation

Battery Charging

Electrical System: Electrical System Operation
The Greensmaster machines uses a 48 VDC lithium-ion battery pack to supply
electrical power to the Toro electronic controller (TEC), an electric motor, and a
main contactor. Circuit protection for this 48 VDC system includes 3 fuses that
reside in the wire harness fuse block.
The battery pack provides a 48 VDC supply and includes a battery management
system. The battery management system uses CAN communication with the
TEC and battery charger.
A Toro Electronic Controller (TEC) is used on the e1021/e1026 machines to
manage the machine electrical functions. The controller is microprocessor
controlled that senses the condition of various switches (inputs) and directs
electrical power to control appropriate machine functions (outputs) based on
the inputs.
The electric motor used on the machine is a 48 VDC, brushless, permanent
magnet DC motor. The motor has its own integral controller. The machine TEC
provides motor direction with communication via the CAN-bus system. The
motor provides power for the traction drum and cutting unit when engaged by
the operator.
The main contactor exists in the electrical system to connect the battery pack
to the electric motor. The TEC determines when the main contactor should
be engaged.
Control for the components in the electrical system is handled by integral
controllers in the battery pack and electric motor along with direction from the
machine TEC via the CAN-bus system.
The InfoCenter display provides information to the operator during the operation
of the machine, provides electrical system diagnostic assistance for the
technicians, and allows inputs for the adjustable machine settings. The status of
TEC inputs and outputs can be monitored with the InfoCenter display.
The 48 VDC system is an isolated system so that the machine frame is not used
for any ground connections on the e1021/e1026 machine. A set of connectors
are included on the machine, which can be used to disconnect the machine
wire harness from the battery pack to prevent unexpected machine operation
when performing service.
Note: Information about individual electrical components in the electrical system
is included in
Testing the Electrical Components (page
The lithium ion battery pack requires regular charging that is provided by the
lithium battery pack charger. The output voltage and current of the charger
are controlled with CAN communication with the battery management system.
Ensure that the charger is connected to the battery pack whenever the machine
is not in use.
Refer to the Operator's Manual for battery charging and battery charger
operation information. Refer to Battery Charger Error and Fault Codes in this
manual for battery charger troubleshooting information.