Cleaning
The pipes and hoses should be pre cleaned, inspected and sealed by the supplier. If
the pipes are field bent and installed the overall system must be carefully oil flushed
to reach the required cleanliness level.
Mounting of hoses
Ensure that hoses not are stressed or twisted on installation, to avoid premature
failure. Bend radius should conform to manufacturers recommendations.
DD00073548
Fig. 14: Mounting of hoses
Hägglunds DOb, RE 15327-WA/05.2017, Installation and maintenance manual, Bosch Rexroth AB
Right
Wrong
Right
Right
Right
Right
Installation
Wrong
Wrong
Wrong
Wrong
29/80