BKM-129X Analog Component Input Adaptor
Assigning input signals to connectors
Before inputting signals to the BKM-129X, you must
specify the type and format of the signal that will be
input to each connector.
For information about the signal assignment, refer to the
manual of your video monitor.
Signal assignment is not necessary for the LMD series
monitors.
Note
After assigning input signals to each connector, carry
out the auto chroma/phase adjustment.
For BVM-D9H/D14H series, carry out AUTO adjustment in
the CONTROL PRESET ADJ menu and for PVM-D20L/
D14L and PVM-20L/14L series, auto chroma/phase
adjustment.
Specifications
General
Power requirements +5 V, ±6 V (supplied from the
monitor)
Power consumption 0.5 W
Operating conditions
Temperature
0°C to 35°C (32°F to 95°F)
Optimum temperature
20°C to 30°C (68°F to 86°F)
Humidity
0% to 90% (no condensation)
Pressure
700 hPa to 1060 hPa
Storage and transport conditions
Temperature
–10°C to 40°C (14°F to 104°F)
Humidity
0% to 90%
Pressure
700 hPa to 1060 hPa
Maximum external dimensions (w/h/d)
25 × 162 × 122 mm
(1 × 6
(1-slot size)
Mass
250 g (9 oz)
10
(E)
× 4
1
7
/
/
inches)
2
8
Input/output connectors
Y/P
/P
, RGB signals
B
R
BNC × 3, high impedance, with loop-through output
and 75-ohm automatic termination
EXT SYNC signals
BNC × 1, with loop-through output and 75-ohm
automatic termination
Signal characteristics
Analog component (Y/P
Signal level
Y/P
(B-Y)/P
(R–Y)
B
R
Y: 1 Vp-p ±6 dB
P
(B–Y): 0.7 Vp-p ±6 dB
B
P
(R–Y): 0.7 Vp-p ±6 dB
R
R/G/B
1 Vp-p ±6 dB (sync on G)
Frequency characteristics
Y
48 Hz to 30 MHz ±3 dB
P
(B-Y)/P
(R–Y) 48 Hz to 30 MHz ±3 dB
B
R
R/G/B
48 Hz to 30 MHz ±3 dB
Return loss
40 dB min. (10 MHz)
EXT SYNC (external sync) signals
Signal level
EXT SYNC
0.3 to 8 Vp-p
Return loss
40 dB min. (6 MHz)
Accessories supplied
Installation Manual (1)
Design and specifications are subject to change
without notice.
/P
, RGB) signals
B
R