Removing and Replacing Field-Replaceable Units
Figure 5-6
Step 5
Pull out the filter tray far enough to remove the air filter
Figure 5-7
Step 6
Place the new air filter in the tray so that you can see the directional arrows located on the metal frame
(pointing up) and slide the tray into the chassis
Step 7
Tighten the captive screws to secure the filter to the chassis
Slide the blower module back into the chassis making sure it securely connects to the backplane
Step 8
(Figure
Step 9
Tighten the captive screws on each side of the blower module
Return all interface cables through the cable management brackets.
Step 10
Replace the front cover if necessary (see the
Step 11
Cisco 10008 Router Hardware Installation Guide
5-8
Removing the Air Filter
PO W ER
FA UL T
M IS W IR
E
Inserting the New Air Filter
PO W ER
FA UL T
M IS W IR
E
5-12). The FANS OK LED should light (green).