Appendix D
Error and Event Messages
Table D-1
Error and Event Messages (continued)
Message
DOT11-4-NO_SSID: No SSIDs
configured, radio not started
DOT11-4-FLASHING_RADIO:
Flashing the radio firmware ([chars])
DOT11-2-NO_FIRMWARE: No radio
firmware file ([chars]) was found
DOT11-2-BAD_FIRMWARE: Radio
firmware file ([chars]) is invalid
DOT11-4-FLASH_RADIO_DONE:
Flashing the radio firmware completed
DOT11-4-LINK_DOWN: Radio parent
lost: [chars]
DOT11-4-CANT_ASSOC: Cannot
associate: [chars]
Inter-Bridge Protocol Messages
DOT11-6-ROAMED: Station
[mac-address] Roamed to [mac-address]
DOT11-6-STANDBY_ACTIVE:
Standby to Active, Reason = [chars]
([int])
DOT11-6-ROGUE_AP: Rogue AP
[mac-address] reported. Reason: [chars]
SCHED-3-UNEXPECTEDMESSAGE:
Unknown message [hex] received (ptr
arg [hex], num arg [hex]).
SCHED-3-UNEXPECTEDEVENT:
Process received unknown event (maj
[hex], min [hex]).
OL-4059-01
Explanation
All SSIDs were deleted from the
configuration. At least one must be
configured for the radio to run.
The radio has been stopped to load new
firmware.
When trying to Flash new firmware into
the radio, the file for the radio was not
found in the Flash file system.
When trying to Flash new firmware into
the radio, the file was found to be invalid.
The radio firmware Flash is complete,
and the radio will be restarted with the
new firmware.
The connection to the parent bridge was
lost for the displayed reason. The unit
will try to find a new parent bridge.
The unit could not establish a connection
to a parent bridge for the displayed
reason.
A station has roamed to a new bridge.
The bridge is transitioning from standby
mode to active mode.
A station has reported a potential rogue
bridge for the stated reason.
A process can register to be notified when
various events occur in the router. This
message indicates that a process received
a message from another process that it
does not know how to handle.
A process can register to be notified when
various events occur in the router. This
message indicates that a process received
an event that it did not know how to
handle.
Cisco Aironet 1400 Series Wireless Bridges Software Configuration Guide
Recommended Action
Configure at least one SSID on the
bridge.
None.
The wrong image has been loaded into
the unit. Locate the correct image based
on the type of radio used.
Put the correct firmware image file in
the place where the unit is looking.
None.
None.
Check the configuration of both the
parent bridge and this unit to make sure
the basic settings (SSID, WEP, and
others) match.
None.
None.
None.
Copy the error message exactly as it
appears, and report it to your technical
support representative.
Copy the error message exactly as it
appears, and report it to your technical
support representative.
D-3