hit counter script

Configuring Rmon; Default Rmon Configuration; Configuring Rmon Alarms And Events - Cisco 3845 - Security Bundle Router Software Manual

Software configuration guide
Hide thumbs Also See for 3845 - Security Bundle Router:
Table of Contents

Advertisement

Chapter 23

Configuring RMON

Configuring RMON

Default RMON Configuration

RMON is disabled by default; no alarms or events are configured.

Configuring RMON Alarms and Events

You can configure your switch for RMON by using the command-line interface (CLI) or an
SNMP-compatible network management station. We recommend that you use a generic RMON console
application on the network management station (NMS) to take advantage of the RMON network
management capabilities. You must also configure SNMP on the switch to access RMON MIB objects.
For more information, see
64-bit counters are not supported for RMON alarms.
Note
Beginning in privileged EXEC mode, follow these steps to enable RMON alarms and events. This
procedure is required.
Command
Step 1
configure terminal
Step 2
rmon alarm number variable interval {absolute
| delta} rising-threshold value [event-number]
falling-threshold value [event-number]
[owner string]
OL-23400-01
Default RMON Configuration, page 23-3
Configuring RMON Alarms and Events, page 23-3
Collecting Group History Statistics on an Interface, page 23-5
Collecting Group Ethernet Statistics on an Interface, page 23-5
Chapter 25, "Configuring SNMP."
(required)
Purpose
Enter global configuration mode.
Set an alarm on a MIB object.
For number, specify the alarm number. The range is 1 to
65535.
For variable, specify the MIB object to monitor.
For interval, specify the time in seconds the alarm monitors
the MIB variable. The range is 1 to 4294967295 seconds.
Specify the absolute keyword to test each MIB variable
directly. Specify the delta keyword to test the change
between samples of a MIB variable.
For value, specify a number at which the alarm is triggered
and one for when the alarm is reset. The range for the rising
threshold and falling threshold values is -2147483648 to
2147483647.
(Optional) For event-number, specify the event number to
trigger when the rising or falling threshold exceeds its limit.
(Optional) For owner string, specify the owner of the alarm.
Cisco ME 3800X and 3600X Switch Software Configuration Guide
Configuring RMON
(optional)
(optional)
23-3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Me 3800xMe 3600x

Table of Contents