Error Symptom
Not all drives are recognized by fixed
disk diagnostic.
System hangs during fixed disk
diagnostic.
POST error codes
In the following error codes, X can be any number or letter.
Error Code/Symptom
062 (Three consecutive boot failures using
the default configuration.)
101, 102 (System and processor error)
106 (System and processor error)
114 (Adapter read-only memory error)
129 (Internal cache error)
151 (Real time clock error)
161 (Real time clock battery error)
162 (Device Configuration Error)
Note: Be sure to load the default settings
and any additional desired settings; then,
save the configuration.
163 (Real-Time Clock error)
164 (Memory configuration changed, see
"Memory settings" on page 34.)
165 (Service Processor failure)
175 (Hardware error)
FRU/Action
1. Remove first drive that does not show up and rerun diagnostic. If
remaining drives show up, replace the one that was removed.
2. If remaining drives do not show up, remove successive drives one
at a time and rerun diagnostic.
1. Remove hard drive being tested at the time of the hang and
rerun the diagnostic. If successful, replace drive that was removed.
FRU/Action
1. Run Configuration/Setup
2. Battery
3. System Board
4. Processor
1. System Board
1. System Board
1. Failing Adapter
2. Run Diagnostics
1. Processor
2. Optional Processor (if installed)
3. System Board.
1. Run Diagnostics
2. Battery
3. System Board
1. Run Configuration/Setup
2. Battery
3. System Board
1. Run Configuration/Setup
2. Battery
3. Failing Device
4. System Board
1. Run Configuration/Setup
2. Battery
3. System Board
1. Run Configuration/Setup
2. DIMM
3. System Board.
1. System Board.
1. System Board
121
Symptom-to-FRU index