Chapter 2 Catalyst 3750 Switch Cisco IOS Commands
This example shows how to display information about stack member 3 from the master switch:
Switch> show env stack 3
SWITCH: 3
FAN is OK
TEMPERATURE is OK
POWER is OK
RPS is NOT PRESENT
This example shows how to display the temperature value, state, and the threshold values.
describes the temperature states in the command output.
Switch> show env temperature status
Temperature Value:28 Degree Celsius
Temperature State:GREEN
Yellow Threshold :70 Degree Celsius
Red Threshold
Table 2-22 States in the show env temperature status Command Output
State
Green
Yellow
Red
78-16181-03
:75 Degree Celsius
Description
The switch temperature is in the normal operating range.
The temperature is in the warning range. You should check the external temperature
around the switch.
The temperature is in the critical range. The switch might not run properly if the
temperature is in this range.
Catalyst 3750 Switch Command Reference
show env
Table 2-22
2-343