errdisable recovery
errdisable recovery
Use the errdisable recovery global configuration command on the switch stack or on a standalone
switch to configure the recover mechanism variables. Use the no form of this command to return to the
default setting.
Syntax Description
cause
all
bpduguard
arp-inspection
channel-misconfig
dhcp-rate-limit
dtp-flap
gbic-invalid
l2ptguard
link-flap
loopback
pagp-flap
psecure-violation
security-violation
udld
Catalyst 3750 Switch Command Reference
2-100
errdisable recovery {cause {all | arp-inspection | bpduguard | channel-misconfig |
dhcp-rate-limit | dtp-flap | gbic-invalid | l2ptguard | link-flap | loopback | pagp-flap |
psecure-violation | security-violation | udld | vmps} | {interval interval}
no errdisable recovery {cause {all | arp-inspection | bpduguard | channel-misconfig |
dhcp-rate-limit | dtp-flap | gbic-invalid | l2ptguard | link-flap | loopback | pagp-flap |
psecure-violation | security-violation | udld | vmps} | {interval interval}
Enable error disable to recover from a specific cause.
Enable the timer to recover from all error-disable causes.
Enable the timer to recover from the bridge protocol data unit (BPDU) guard
error-disable state.
Enable the timer to recover from the Address Resolution Protocol (ARP)
inspection error-disable state.
Enable the timer to recover from the EtherChannel misconfiguration
error-disable state.
Enable the timer to recover from the DHCP snooping error-disable state.
Enable the timer to recover from the Dynamic Trunking Protocol (DTP) flap
error-disable state.
Enable the timer to recover from an invalid Gigabit Interface Converter
(GBIC) module error-disable state.
Note
Enable the timer to recover from a Layer 2 protocol tunnel error-disable state.
Enable the timer to recover from the link-flap error-disable state.
Enable the timer to recover from a loopback error-disable state.
Enable the timer to recover from the Port Aggregation Protocol (PAgP)-flap
error-disable state.
Enable the timer to recover from a port security violation disable state.
Enable the timer to recover from an 802.1x violation disable state
Enable the timer to recover from the UniDirectional Link Detection (UDLD)
error-disable state.
Chapter 2
On the Catalyst 3750 switch, this error refers to an invalid small
form-factor pluggable (SFP) error-disable state.
Catalyst 3750 Switch Cisco IOS Commands
78-16181-03