Appendix B
Catalyst 3750-X and 3560-X Switch Debug Commands
debug platform ipc
Use the debug platform ipc privileged EXEC command to enable debugging of the platform-dependent
Interprocess Communication (IPC) Protocol. Use the no form of this command to disable debugging.
This command is supported only on Catalyst 3750-X switches.
Note
Syntax Description
all
init
receive
send
trace
Defaults
Debugging is disabled.
Command Modes
Privileged EXEC
Command History
Release
12.2(53)SE2
Usage Guidelines
The undebug platform ipc command is the same as the no debug platform ipc.
When you enable debugging on a switch stack, it is enabled only on the stack master. To enable
debugging on a stack member, you can start a session from the stack master by using the session
switch-number privileged EXEC command. Then enter the debug command at the command-line
prompt of the stack member. You also can use the remote command stack-member-number LINE
privileged EXEC command on the stack master switch to enable debugging on a member switch without
first starting a session.
Related Commands
Command
show debugging
OL-29704-01
debug platform ipc {all | init | receive | send | trace}
no debug platform {all | init | receive | send | trace}
Display all platform IPC debug messages.
Using this command can degrade the performance of the switch.
Note
Display debug messages related to IPC initialization.
Display IPC traces each time an IPC packet is received by the switch.
Display IPC traces each time an IPC packet is sent by the switch.
Display IPC trace debug messages, tracing the code path as the IPC functions are
executed.
Modification
This command was introduced.
Description
Displays information about the types of debugging that are enabled.
Catalyst 3750-X and 3560-X Switch Command Reference
debug platform ipc
B-61