hit counter script

Digital Signal Processing - Dalsa spyder SG-10-01k80 User Manual

Gige spyder 3 camera gige dual line scan camera
Hide thumbs Also See for spyder SG-10-01k80:
Table of Contents

Advertisement

Spyder 3 GigE User's Manual

Digital Signal Processing

To optimize camera performance, digital signal processing should be completed after any
analog adjustments.
FPN Correction
Performing FPN Correction
Syntax:
Syntax:
Notes:
Related Commands:
Example:
Setting a Pixel's FPN Coefficient
Purpose:
Syntax
Syntax Elements:
Example:
DALSA
Performs FPN correction and eliminates FPN noise by subtracting
away individual pixel dark current.
ccf
Perform all analog and digital adjustments before
performing FPN correction.
Perform FPN correction before PRNU correction.
Refer to
C alibrating the Camera to Remove Non-Uniformity
2 8 6 H
(Flat Field Correction)on page
on performing flat field correction.
To save FPN coefficients after calibration, use the
command. Refer to section
PRNU and FPN Coefficients for details.
The QuickCam software that ships with the Spyder 3 GigE
camera has a flat field correction wizard. For easy flat field
correction, use the wizard located on the Calibration tab.
c
cp,
w fc
8 6 H
8 7 H
ccf
Sets an individual pixel's FPN coefficient.
sfc x i
x
The pixel number from 1 to sensor pixel count .
i
Coefficient value in a range from 0 to 2047 (12 bit LSB).
sfc 10 50
7 0 for a procedural overview
2 8 7 H
w fc
8 5 H
A 3.1 Saving and Restoring
2 8 8 H
03-032-10158-06
73

Advertisement

Table of Contents
loading

This manual is also suitable for:

Spyder sg-10-02k80Spyder sg-10-01k40Spyder sg-10-02k40

Table of Contents