hit counter script

Mounting The Lens - Sony SRW-9000PL Operation Manual

Hdcam sr format digital cinematography camcorder
Hide thumbs Also See for SRW-9000PL:
Table of Contents

Advertisement

A 15-segment bar graph (maximum value: 10 A)
displays the unit's operating current.
The bar graph flashes red in the following cases.
• When the input current to the DC IN 11-17V
connector exceeds 9 A.
• When one of the unit's internal power systems
has been disconnected.
Note
To protect the unit from excessive current inflows,
alarms or error messages may appear when you have
connected other devices to it.
For details, see "Warning/Error Messages" (page
188).
To check the remaining battery power
You can check the remaining battery power with
the battery level display.
As the battery pack discharges, the segments go
out from left to right.
When the battery pack is almost exhausted (Near
END), the voltage indication and the tally
indicator start to flash, and an intermittent
warning tone sounds in the headphones.
When the battery pack is completely exhausted
(END), the corresponding warning indication
lights, the tally indicator starts to flash at a higher
rate, and the headphones warning tone sounds
continuously.
You can use BATTERY (see page 171) of the
SYSTEM Setup menu to set the battery voltage
threshold values that trigger the END and Near
END warnings.
You can check the power voltage in the subdisplay, in
the viewfinder, and on an external monitor. For
details, see "Checking the Power Voltage and
Selecting the Fan Mode" (page 52) and "Viewing
Settings and Indications in the Viewfinder" (page
62)
For details on the warning tone, see "Warning
System" (page 186).

Mounting the Lens

Attach an appropriate optional lens that conforms
to the PL lens mount.
Note
Always use a lens whose projection from the flange (A
in the figure) is less than 30 mm. Use of any lens that
protrudes more than 30 mm will damage the internal
filter.
For information on handling lenses, refer to the lens'
operation manual.
1
Rotate the lens fixing levers
counterclockwise and remove the lens
mount cap from the lens mount.
2
Align the lens' alignment pin with the
notch in the upper part of the lens
mount and insert the lens into the
mount.
Lens fixing levers
Mounting the Lens
31

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hksr-9001Hksr-9002

Table of Contents