Cisco ASR 1002 Router Power Supplies
To connect +24 VDC power supply in the Cisco ASR 1002 Router, follow these steps:
At the rear of the router, check that the power Standby switch is in the Standby position.
Step 1
Ensure that the positive and negative leads are disconnected from the site power source and the source
Step 2
circuit breaker is turned off.
Using a wire stripper, strip the recommended amount of wire insulation which is 15mm (0.6 inch) from
Step 3
the negative, positive, and ground leads.
Note
Figure 8-29
Figure 8-29
1
Lead wire stripping area
Remove the covering from exactly the specified length of each wire. If you strip too much of the
Warning
covering, exposed wire protruding from the terminal block will create an electrical hazard. If you
strip too little of the covering, the wire might not make a good contact with the terminal, or it might
not be held securely in place in the terminal.
Cisco ASR 1000 Series Aggregation Services Routers Hardware Installation Guide
8-40
The stripping length is common to all types of wire used.
shows the wire strip and lead.
Stripping Wire for the +24 VDC Terminal Block
1
Chapter 8
Cisco ASR 1002 Router Overview and Installation
— —
OL-13208-11