hit counter script

Warning/Error Messages; Warning And Error Messages Related To The Camera Module - Sony SRW-9000PL Operation Manual

Hd camcorder
Hide thumbs Also See for SRW-9000PL:
Table of Contents

Advertisement

Warning/Error Messages

Warning and Error Messages Related to the Camera Module

If low battery power is detected, or if an error or other abnormal condition occurs on power on or during
operation, the RUN indicator flashes and alarm message flash on the viewfinder, on an external monitor,
and in the subdisplay.
Viewfinder screen
Basic status
Message
display (see
page 64)
BATT flashes
BATT flashes
SHUTDOWN
CAMERA/FAN MAX
OHB FAN NG!
MAIN FAN NG!
CAM?
OHB NG!
CAM?
AD BOARD NG!
CAM?
VDA BOARD NG!
CAM?
VPR BOARD NG!
VTR ERROR
XXXX
TEMPERATURE
CARE
TEMP WARNING/
FAN MAX
POWER OFF TO SET
CAM ERROR!
POWER OFF->ON
REF UNLOCK
VTR WARNING
XXXX
202
Warning/Error Messages
Subdisplay
RUN indicator Meaning
BATT flashes
Flashes
BATT flashes
Flashes quickly Power voltage is exhausted (has
quickly
Power voltage is low (has reached
the specified NEAR END value).
reached the specified END value).
The unit must be powered off for
safety. FAN MODE has been
forcibly set to MAX.
The fan near the CCD has stopped.
The fan in the main unit has
stopped.
CCD unit error
AD board error
VDA board error
VPR board error
Error in the VTR module
XXXX: error code (see page 203)
The temperature inside the unit is
high.
The temperature inside the unit has
risen to the limit. FAN MODE has
been forcibly set to MAX.
Memory checksum error or other
error occurred.
The unit must be powered off.
Changing formats or other
operation failed.
The unit must be powered off and
on again.
When REFERENCE on the
<GENLOCK> page of the Camera
>MAINTENANCE menu is set to
GENLOCK IN or AUX IN, an
improper signal was detected.
Warning in the VTR module
XXXX: error code (see page 203)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hksr-9001Hksr-9002

Table of Contents