Item
Function
H POS
For setting the horizontal
position of the indication in the
range of 0 to 99 (0 is the
leftmost.)
V POS
For setting the vertical position
of the indication in the range of 0
to 99 (0 is the uppermost.)
Outputting Color Bars
Color bar signals can be output from the unit's
internal color bar generator.
Use the <OTHERS 1> page of the Camera
>USER (MAINTENANCE) menu.
<OTHERS 1> page
When CAM BARS is set to ON, the color bar
generator is turned on, and the color bar signal is
output.
For the HD output (to the viewfinder and
monitor) and SD (VBS) output, the format of the
color bar signals can be independently selected.
Regardless of HD output and SD output settings,
the main line output is always a 16:9 (100%)
color bar signal.
HD-BAR (VF/MON)
You can select the formats of the color bar signals
sent to the VF, HD SDI MON1 and HD SDI
MON2 connectors from among 17 types.
SD-BAR
You can select the formats of the color bar signals
to the TEST OUT and REMOTE connectors from
among five types.
Item
Selectable color-bar formats
HD-BAR
BAR 16:9 (100%), BAR 16:9
(VF/MON)
(75%), SMPTE 16:9 (BLACK)
BAR 4:3 (100%), BAR 4:3 (75%),
SMPTE 4:3 (BLACK), MF-ARIB
(75%), MF-ARIB (100%), MF-
ARIB (+I), MF-SMPTE (–I, Q)
62
Setting the Camera Outputs
Item
Selectable color-bar formats
SD-BAR
SMPTE, EIA, FULL (EBU), 95%,
NTSC100% (PAL100%)
Note
The color bar signal is not output with the video output
from the VF, HD SDI MON1, HD SDI MON2, and
REMOTE connectors if the monitor LUT (R709) is
selected for MLUT/PBMIX of the respective output on
the <PB/MON LUT> page (see page 132) (except when
a VBS signal is output).
Outputting Rec Trigger Signals
By outputting Rec Trigger signals to an SRW-1/
SRPC-1 connected to the HD SDI MON1 or HD
SDI MON2 connector or the HD SDI OUT A/B
connector (when the HKSR-9001 is installed),
you can configure a function that enables
recording in conjunction with the unit.
Use the <OTHERS 1> page of the Camera
>USER (MAINTENANCE) menu.
<OTHERS 1> page
Notes
• Even if there is no cassette loaded in the unit or the tape
ends, Rec Trigger signals will be output when you
press the REC button (or RUN button).
• If the tape ends or the cassette is removed while Rec
Trigger signals are being output, tape recording will
start when you load a new cassette and press the REC
button (or RUN button).
Set SDI REMOTE to CHAR, G-TLY, or R-TLY.
Depending on the status of the unit, the
viewfinder, unit tally indicator, and control panel
displays will be as follows.