Step 5 Push press-fitting sleeve A towards the connector. Compact the outer conductor of the coaxial
cable. Press-fit sleeve A and the plug of the coaxial connector by using press-fitting tools, as
shown in
Figure A-44 Press-fitting the outer conductor
Step 6 Press-fit upper cover B on plug C of the connector, as shown in
Figure A-45 Press-fitting the upper cover on the connector
B
----End
Follow-up Procedure
After assembling the cable components, install the components on devices, as shown in
A-46.
Issue 01 (2012-07-25)
NOTE
After the welding, make sure that there is no metal wire (especially of the outer conductor) or redundant
soldering tin between the inner conductor and the outer conductor. Use the multimeter to test the insulation
state between the inner conductor and the outer conductor. Then, press-fit the outer conductor.