Data In The Modbus Registers (Data Mapping) - Siemens SICAM Q100 System Manual

Class a power quality instrument and power monitoring device
Hide thumbs Also See for SICAM Q100:
Table of Contents

Advertisement

Communication
2.2 Modbus
Quality Information
The two following quality bits are stored for each counter in separate holding registers:
Overflow OV: The internal counter pulse exceeds 31 bits. The Overflow bit is reset once the counter has
been reset.
Invalid IV: The counter value is invalid due to a reset/device start. The bit is deleted 1 min after the device
start.
OV
IV
Counter 8
Energy per Counter Pulse
The energy per counter pulse is identical for all energy metered values calculated from the measured AC quan-
tities so that only one value is transmitted for all energy counters. The energy per counter pulse is determined
by the AC network configuration.
At the rated value 60 000 counter pulses per hour are recorded for V
A counter overflow occurs about 4 years after the counters were reset when V
continuously.
2.2.7

Data in the Modbus Registers (Data Mapping)

The indications, measured values etc. are stored in Holding registers. The following register groups exist. They
are described in the following sections:
Register 0001 to 0048:
Register 0065 to 0068:
Register 0071 to 0088:
Register 0101/0102:
Register 0111/0112:
Register 0113:
Register 0114:
Register 0131:
Register 0132:
Register 0135 and 0137:
Register 0136 and 0138:
Register 0141 to 0150:
Register 0151:
Register 0152:
Register 0153:
Register 0154:
28
OV
IV
OV
IV
OV
Counter 7
Counter 6
Holding register 08xx
Device identification (read only)
Date and time (read and write)
Version information (read only)
Device status (read only)
Indications concerning limit violations (read only)
Group indications (read only)
PQ events (read only)
Status of the binary outputs (read only)
Status of the binary inputs (read only)
Status of binary inputs of SICAM IO subdevice (read only)
Status of binary outputs of SICAM IO subdevice (read only)
Messages of the communication (read and write)
Load profiles (write only)
Load profiles (read only)
Synchronization of load profile measuring period (read and write)
Tariffs (read and write)
IV
OV
IV
OV
Counter 5
Counter 4
Counter 3
rated
IV
OV
IV
OV
Counter 2
Counter 1
and I
.
rated
and I
are measured
rated
rated
SICAM Q100, 7KG95xx, System Manual
E50417-C1040-C522-A8, Edition 09.2020
IV