■Error detection (X5, XD)
When ID command execution request (Y14, Y1C) is turned on and ID command is completed with error, Error detection (X5,
XD) turns on. In this case, ID command complete (X4, XC) does not turn on.
When ID command execution request (Y14, Y1C) is turned off and received by the RFID interface module, Error detection
(X5, XD) turns off.
When the watchdog timer error occurs, Error detection (X5, XD) does not turn on. (RUN LED turns off.)
ID command execution request
(Y14, Y1C)
ID-BUSY (X3, XB)
ID command complete (X4, XC)
Error detection (X5, XD)
Error details storage area
(Un\G41, Un\G4041)
(1) When the ID command is completed with error, Error detection (X5, XD) turns on.
(2) When ID command execution request (Y14, Y1C) is turned off, Error detection (X5, XD) turns off.
(3) The error is cleared and Error details storage area (Un\G41, Un\G4041) becomes 0.
APPX
124
Appendix 2 I/O Signals
0
Error details
(1)
Controlled by the RFID interface module
Controlled by the program
(2)
0
(3)