2.
Adjust the levels of other channels to a channel that the portion B on waveform is the lowest level.
• Adjustment item: [R], [G], [B]
B
3.
Store the reference file.
(Refer to
"6-4-13. File
Store".)
6-4-10.
Gamma Correction Adjustment
Equipment: Waveform monitor (R, G, B)
Test point: SDI OUT connector
Subject: Grayscale chart
Preparation
• Setting for the MSU
KNEE OFF button → OFF (lit)
GAMMA OFF button → ON (unlit)
• Shoot the grayscale chart so that it is aligned with the under scanned monitor frame.
• Lens iris: A = 700 ±20 mV
A
Procedure
1.
Operate the control panel of MSU, and perform the automatic white balance adjustment.
WHITE button → ON (lit)
After the adjustment is completed, the message "AWB: OK" is displayed.
2.
Operate the control panel of MSU, and set as follows.
(1) PAINT button → ON (lit)
(2) Touch panel operation: (Page 1) → [Gamma]
HXC-FB75H/HXC-FB75KC
6-24