Removing and Installing the DC-Input Power Supplies
If you are not going to remove the IPM, skip steps 7 and 8 and go to step 9.
Note
Loosen the IPM captive installation screws on the power supply. See
Step 7
Lift up on both IPM latches and remove the IPM. See
Step 8
Figure 4-43
Step 9
Loosen the captive installation screw on the power supply
Caution
Use both hands to install and remove power supplies. Each DC-input power supply weighs 35 pounds
(16 kg).
Grasp the power supply handle with one hand and slide the power supply part of the way out of the
Step 10
chassis. Place your other hand underneath the power supply, as shown in
in
Figure 4-45
If the power supply bay is to remain empty, install a blank power supply filler plate (Cisco part number
Note
700-03104-01) over the opening, and secure it with the captive installation screws.
Catalyst 6500 Series Switches Installation Guide
4-62
Removing the IPM Module
CI SC O SY
ST EM S, IN
C
1
2
3
IN PU T
OK
(with IPM), and slide the power supply completely out of the chassis.
Chapter 4
Figure
4-43.
4
FA N
OU TP UT
OK
FA IL
(Figure
4-41).
Removal and Replacement Procedures
Figure
4-41.
Figure 4-44
(without IPM) and
OL-5781-08