Appendix D
Chassis and Module Power and Heat Values
Table D-8
Table D-8
Power Requirements and Heat Dissipation—Gigabit Ethernet Modules
Model Number/
Module Type
WS-X6316-GE-TX
16-port 1000BASE-T Gigabit
Ethernet module
WS-X6408A-GBIC
8-port 1000BASE-X Gigabit
Ethernet module
WS-X6416-GBIC
16-port 1000BASE-X Gigabit
Ethernet module
WS-X6416-GE-MT
8-port 1000BASE-SX Gigabit
Ethernet module
WS-X6516-GBIC
16-port 1000BASE-X Gigabit
Ethernet module
WS-X6516A-GBIC
16-port 1000BASE-X Gigabit
Ethernet module
WS-X6724-SFP
24-Port 1000BASE-X Ethernet
module
WS-X6748-SFP
48-Port 1000BASE-X Ethernet
module
WS-X6816-GBIC
16-Port1000BASE-X Gigabit
Ethernet module
OL-5781-08
lists the power and the heat numbers for the Gigabit Ethernet modules.
Module
Module
Current (A)
Power
(Watts)
5.15
216.3
2.00
84.00
2.81
118.02
2.50
105.00
3.40
142.80
3.62
152.04
2.23
99.66
5.32
223.44
3.84
161.28
AC
DC
AC-Input
Heat Diss.
DC-Input
Power
(BTU/HR)
Power
(Watts)
(Watts)
270.38
923.33
290.73
105.00
358.58
112.90
147.53
503.8
158.63
131.25
448.22
141.13
178.50
609.58
191.94
190.05
649.02
204.35
117.08
399.81
125.89
279.30
953.81
300.32
201.60
688.46
216.77
Catalyst 6500 Series Switches Installation Guide
Heat Diss.
(BTU/HR)
992.83
385.56
541.72
481.96
655.46
697.87
429.90
1025.60
740.28