Appendix A
Power Supply Specifications
Table A-26
LED
INPUT OK
FAN OK
OUTPUT FAIL
42V OK
OL-5781-08
3000 W AC-Input Power Supply LEDs
Meaning
Green—Source AC voltage is OK. (Input voltage is 85 VAC or
greater.)
Off—Source AC voltage falls below 70 VAC, is not present, or the
power supply is turned off.
Green—Power supply fan is operating properly.
Off—Power supply fan failure is detected.
Red—Problem with one or more of the DC-output voltages of the
power supply.
Off—DC-output voltages within acceptable margins.
For proper operation of the OUTPUT FAIL LED, systems with
Note
single power supplies must be configured with a minimum of
one fan tray and one supervisor engine. Systems with dual power
supplies must have a minimum configuration of one fan tray, one
supervisor engine, and one additional module. Failure to meet
these minimum configuration requirements can cause a false
power supply output fail signal.
Green—42 VDC is present at the fan power connector.
Off—42 VDC is not present at the fan power connector.
3000 W AC-Input Power Supply
Catalyst 6500 Series Switches Installation Guide
A-39