Catalyst 6513 Switch
Table 1-21
Table 1-21
Catalyst 6513 Switch Features
Feature
Chassis
Supervisor engines
Catalyst 6500 Series Switches Installation Guide
1-62
lists the features of the Catalyst 6513 switch chassis.
Description
•
Thirteen horizontal slots. Slots are numbered from (1) top to (13)
bottom.
•
Supports Supervisor Engine 2, Supervisor Engine 32, Supervisor
Engine 32 PISA, Supervisor Engine 720, and Supervisor
Engine 720-10GE.
Refer to your software release notes for the minimum software
Note
release versions required to support the supervisor engines.
–
Supervisor Engine 2 must be installed in slot 1 and slot 2.
–
Supervisor Engine 32, Supervisor Engine 32 PISA, Supervisor
Engine 720, and Supervisor Engine 720-10GE must be installed in
slot 7 and slot 8.
Slots not occupied by supervisor engines can be used for modules.
Note
Check your software release notes for any restrictions on the type of
module that can be installed.
Supervisor Engine 32, Supervisor Engine 32 PISA, Supervisor
•
Engine 720, and Supervisor Engine 720-10GE require that you install
the high-speed fan tray (WS-C6K-13SLT-FAN2) be installed in the
chassis. You must also install a 2500 W or higher capacity power supply
in the chassis to power the high-speed fan tray.
•
Supervisor Engine 720 and Supervisor Engine 720-10GE have a built-in
switching fabric. Switch Fabric Modules (WS-C6500-SFM and
WS-X6500-SFM2) are not supported by Supervisor Engine 720 and
Supervisor Engine 720-10GE.
Supervisor Engine 32 and Supervisor Engine 32 PISA do not support the
•
Switch Fabric Modules (WS-C6500-SFM and WS-X6500-SFM2).
The uplink ports are fully functional on all redundant supervisor engine
•
models when they are in standby mode.
In systems with redundant supervisor engines, both supervisor
Note
engines must be the same model and have the same daughter card
configurations. Each supervisor engine must have the resources to
run the switch on its own, which means that all supervisor engine
resources are duplicated. Identical supervisor engine memory
configurations are recommended, but are not required as long as the
supervisor engine with the smaller memory configuration is
sufficient to run the configured features of the switch. Additionally,
each supervisor engine must have its own flash device and console
port connections.
Chapter 1
Product Overview
OL-5781-08