Appendix A
Power Supply Specifications
Table A-15
LED
INPUT OK
FAN OK
OUTPUT FAIL

1400 W Power Supply AC Power Cords

Table A-16
power supply. These power cords plug into the 1400 W PEM (PEM-20A-AC+); not directly into the
power supply. The table includes references to power cord illustrations.
All 1400 W power supply power cords are 14 feet (4.3 meters) in length.
Note
All 1400 W power supply power cords have an IEC60320/C19 appliance plug at one end.
Note
OL-5781-08
1400 W AC-Input Power Supply LEDs
Meaning
Green—Source AC voltage is OK. (Input voltage is 85 VAC or
greater.)
Off—Source AC voltage falls below 70 VAC, is not present, or the
power supply is turned off.
Green—Power supply fan is operating properly.
Off—Power supply fan failure is detected.
Red—Problem with one or more of the DC-output voltages of the
power supply is detected.
DC-output voltages within acceptable margins.
Note
lists the specifications for the AC power cords that are available for the 1400 W AC-input
For proper operation of the OUTPUT FAIL LED, systems with
single power supplies must be configured with a minimum of
one fan tray and one supervisor engine. Systems with dual power
supplies must have a minimum configuration of one fan tray, one
supervisor engine, and one additional module. Failure to meet
these minimum configuration requirements can cause a false
power supply output fail signal.
Catalyst 6500 Series Switches Installation Guide
1400 W AC-Input Power Supply
A-21