hit counter script

Cisco Sx350 Cli Manual page 1192

Hide thumbs Also See for Sx350:
Table of Contents

Advertisement

62
1191
Display the power supply status
power -
fan
Displays the fan status
temperature status—Displays the temperature status
Command Mode
User EXEC mode
User Guidelines
The power parameters displays power supply information.
Main Power supply statuses:
Active - power supply is used.
Failure - Main power has failed.
PD
Power supply statuses:
Active - power supply is used.
Available - Power supply is connected but is not used.
Not Connected - The PD port is not connected or not connected to PSE.
The fan and temperature status parameters are available only on devices on which
FAN and/or temperature sensor are installed.
Fan status can be one of:
Fans OK, redundant fan Ready - The fan/s functions correctly.
Fans OK, redundant fan Active - One of the fans failed and is backed-up by
the redundant fan.
Fail - Several fans failed.
N/A - No fan installed.
Sensor status can be one of:
OK - The sensor/s functions correctly.
Failure - The sensor/s failed.
NA - No sensor is installed.
Temperature can be one of:
Cisco Sx350 Ph. 2.2.5 Devices - Command Line Interface Reference Guide
System Management Commands

Advertisement

Table of Contents
loading

Table of Contents