45
911
Example
The following example displays information about the inline power consumption.
switchxxxxxx# show powered-device
Port
PD
standard
-----
--------
gi11
802.3AT
gi12
802.3AT
Field
Description
PD standard
This indicated the PD port physical capability.
Power
This indicates the PD requested power (as
Requested
requested from the PSE side in Watts).
If port is forced to specific power, the value
reflects the forced power and is indicated by "
(Forced) ".
If port is not connected to PSE or is in down
state the status is N/A.
If CDP/LLDP negotiation is activated than this
represent the maximum request power level.
If no negotiation is activated this value is
derived from the PD standard.
Power
PSE standard
Requested(W)
(link partner)
------------
-------------
25.5
802.3AT
25.5(forced)
802.3AF
Cisco Sx350 Ph. 2.2.5 Devices - Command Line Interface Reference Guide
Power over Ethernet (PoE) Commands
Power
Available(W)
------------
25.5 (CDP)
Unknown(LLDP)