hit counter script

Action Forceshut - Cisco AJ732A - MDS 9134 Fabric Switch Command Reference Manual

Cisco mds 9000 family command reference guide - release 4.x (ol-18089-01, february 2009)
Hide thumbs Also See for AJ732A - Cisco MDS 9134 Fabric Switch:
Table of Contents

Advertisement

Chapter 2
A Commands
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m

action forceshut

To configure a forced shutdown of a module, a crossbar, ASCII or the entire switch when an Embedded
Event Manager (EEM) applet is triggered, use the action forceshut command.
Syntax Description
number
.number2
module slot
xbar xbar-number
reset-reason
Defaults
None.
Command Modes
Embedded Event Manager mode.
Command History
Release
NX-OS 4.1(3)
Usage Guidelines
None.
Examples
The following example shows how to log an EEM applet exception:
switch# configure terminal
switch(config)# event manager applet exception-applet
switch(config-applet)# action 1.0 forceshut module 2 reset-reason "flapping links"
switch(config-applet)#
Related Commands
Command
event manager applet
OL-18089-02, Cisco MDS NX-OS Release 4.x
action number [.number2] forceshut [module slot | xbar xbar-number] reset-reason seconds
Number can be any number up to 16 digits. The range for number2 is from
0 to 9.
(Optional) Specifies slot range. The range is from 1 to 10, or a substituted
parameter.
(Optional) Specifies xbar-number. The range is from 1 to 4 or a substituted
parameter.
Specifies reset reason. The reason is a alphanumeric string up to 80
characters.
Modification
This command was introduced.
Description
Displays an applet with the Embedded Event Manager.
Cisco MDS 9000 Family Command Reference
action forceshut
2-17

Advertisement

Table of Contents
loading

Table of Contents