hit counter script

Significance Of Fcs - Cisco AP776A - Nexus Converged Network Switch 5020 Configuration Manual

Cisco mds 9000 family cli configuration guide - release 4.x (ol-18084-01, february 2009)
Hide thumbs Also See for AP776A - Nexus Converged Network Switch 5020:
Table of Contents

Advertisement

About FCS
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
In
Figure 55-1
and Management Application 2 (M2) is connected through an F port with port VSAN ID 2. M1 can query
the FCS information of switches S1 and S3, and M2 can query switches S3 and S4. Switch S2
information is not known to both of them. FCS operations can be done only on those switches that are
visible in the VSAN. Note that M2 can send FCS requests only for VSAN 2 even though S3 is also a part
of VSAN 1.
Figure 55-1
Management
Application 1

Significance of FCS

This section lists the significance of FCSs.
Cisco MDS 9000 Family CLI Configuration Guide
55-2
Management Application 1 (M1) is connected through an F port with port VSAN ID 1,
FCSs in a VSAN Environment
(port VSAN=2)
VSAN 1
ISL1
N port
Switch 1
(dFCS1)
F port
(port VSAN=1)
FCSs support network management including the following:
N port management application can query and obtain information about fabric elements.
SNMP manager can use the FCS management information base (MIB) to start discovery and
obtain information about the fabric topology.
FCSs support TE and TL ports in addition to the standard F and E ports.
FCS can maintain a group of modes with a logical name and management address when a platform
registers with it. FCSs maintain a backup of all registrations in secondary storage and update it with
every change. When a restart or switchover happens, FCSs retrieve the secondary storage
information and rebuild its database.
SNMP manager can query FCSs for all IEs, ports, and platforms in the fabric.
Chapter 55
Management
Application 2
F port
VSAN 2
Switch 3
(dFCS3)
ISL2
Switch 4
(dFCS4)
ISL3
Switch 2
(dFCS2)
VSAN 3
Configuring Fabric Configuration Servers
OL-18084-01, Cisco MDS NX-OS Release 4.x

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents