hit counter script

Connecting Cables - Cisco VG310 Hardware Installation Manual

Voice gateway
Hide thumbs Also See for VG310:
Table of Contents

Advertisement

Connecting Cables

Tip
Note
Step 2
Strip one end of the ground wire till the length required for the ground lug or terminal is reached.
Step 3
Crimp the ground wire to the ground lug or ring terminal using a crimp tool of the appropriate size.
Figure 12: Chassis Ground Connection Using Ring Terminal
1
Step 4
Attach the ground lug or ring terminal to the chassis as shown in the following figures. For the ground lug,
use the two screws with captive locking washers provided. For a ring terminal, use one of the screws provided.
Use a number 2 Phillips screwdriver and tighten the screws to a torque of 8 in-lb to 10 in-lb (0.9 N-m to 1.1
N-m).
Note
Step 5
Connect the other end of the ground wire to a grounding point at your site.
Connecting Cables
Do not work on the system or connect or disconnect cables during periods of lightning activity. Statement
Warning
1001
Cisco VG310 and Cisco VG320 Voice Gateways Hardware Installation Guide
34
Use a multimeter to measure the resistance between various ground locations:
• Between the ground of a junction box (outlet) and the ground of a
power tap
• Between the ground of a junction box and a metal water pipe
• Between the chassis and the ground of a power tap
• Between the chassis and the ground of a junction box
A good ground connection should read between 0.0 Ω and
0.5Ω.
Ring terminal attachment
You can orient the crimped end of the ground lug in either direction (right or
left).
Installing the Cisco VG310 and Cisco VG320 Voice Gateways
OL-31292-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vg320