Technical data of the components
5.8.2

Hybrid cable without communication, technical data

Description
Brief description of cable
RoHS
Recognized UL and CSA
1)
AWM Style
Diameter
Power core cross section
Cable jacket material
2)
Cable jacket color
Specific cable weight
Temperature range for storage
Ambient temperature at operation
(permanent installation)
Ambient temperature at operation
(flexible installation)
Operating temperature at conduc‐
tor (flexible/permanent)
Leakage capacitance
Conductor resistance at 20°C (EN
60228; class 6)
Operational
voltage
at
cores
Operational voltage at control
cores
Halogens
Oil resistance
Flammability
Flexible cable tracks
Suitable for application in flexible
cable tracks
Bending cycles
Bending radius with flexible instal‐
lation
Bending radius with permanent in‐
stallation
Max. acceleration
3)
Max. travel velocity
4)
Rexroth IndraDrive Mi Drive Systems with KCU02 KSM02, KMS02/03, KMV03, KNK03
Data sheet - bulk cable
Symbol
Unit
D
mm
mm
2
m
kg/m
°C
°C
°C
°C
C
Y_K_typ
R
ohm/km
20
power
V
V
mm
mm
a
m/s²
max
v
m/s
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
DOK-INDRV*-KCU02+KSM02-PR03-EN-P
REH0803
(5x2.5mm² + 5x0.34mm²)StC
RoHS compliant (according to 2011/65/EC)
cURus
AWM21223
11.4 +/-0.3
2.5
PUR
RAL2003
0.234
tbd
-40 ... +80
tbd
tbd
8 (2.5 mm²)
850
100
Halogen-free acc. to VDE 0472, Part 815
tbd
IEC 60332-1-2
Yes
5
8 x D
4 x D
50m/s² (5m)
5