312/337
Bosch Rexroth AG
Commissioning, operation, diagnostics and maintenance
Dismounting
11.4.4
Replacing the component
Rexroth IndraDrive Mi Drive Systems with KCU02 KSM02, KMS02/03, KMV03, KNK03
1. Observe the instructions contained in the machine documentation.
2. Use the machine-side control commands to bring the drive to a control‐
led standstill.
3. Switch off the power voltage and control voltage of the controller.
4. Switch off the main switch of the machine.
5. Secure the machine against accidental movements and against unau‐
thorized operation.
6. Wait to allow the electric systems to discharge and then disconnect all
electrical connections.
7. Before dismounting them, secure the motor and, if necessary, the fan
unit against falling or movements, before unfastening the mechanical
connections.
WARNING
●
Do not work at running or unsecured installations.
●
Before starting to dismount, secure the machine against accidental
movements and unauthorized operation.
●
Before dismounting them, secure the motor and the supply lines unit
against falling or movements, before unfastening the mechanical con‐
nections.
CAUTION
●
Before beginning to work, let the motors cool down. The thermal time
constant specified in the Technical Data is a measure for the time re‐
quired for cooling down. Cooling down can require up to 140 minutes!
●
Do not work at hot surfaces.
●
Wear safety gloves.
1. Observe the instructions contained in the machine documentation.
2. Observe the Safety Instructions and carry out all steps according to the
instructions for "deactivation".
3. Before dismounting them, secure the motor and the supply lines unit
against falling or movements, before unfastening the mechanical con‐
nections.
4. Dismount the motor from the machine.
5. Store the motor appropriately.
Always replace a defective component with a new component of
the same type.
1. De-energize the machine (switch off 24V supply, too!)
2. Make sure main switch cannot be switched on again
3. WARNING! High electrical voltage! Danger to life by electric shock!
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
DOK-INDRV*-KCU02+KSM02-PR03-EN-P
Lethal injury caused by errors when control‐
ling motors and working at moving parts!
Burns caused by hot surfaces with tempera‐
tures of more than 100 °C!