FRSM-4E1 Specification
Statistics:
Diagnostics:
Indicators:
Maintenance/Serviceability
Features:
Card Size:
Power:
Ingress:
Egress:
Cisco MGX 8220 Installation and Configuration
B-16
ATM cells: Number of cells transmitted to BNM
Number of cells transmitted with CLP bit set
Number of OAM AIS cells transmitted (S)
Number of OAM FERF cells transmitted (S)
Number of BCM cells transmitted
Number of OAM end-end loopback cells transmitted (S)
Number of OAM segment loopback cells transmitted
Number of cells received from BNM
Number of cells received with CLP bit set
Number of OAM AIS cells received (S)
Number of OAM FERF cells received (S)
Number of BCM cells received
Number of OAM end-end loopback cells received (S)
Number of OAM segment loopback cells received
Number of OAM cells discarded due to CRC-10 error (S)
All previous counters followed by an (S) can be configured as
statistics.
8 Last unknown LCN received
Cells with unknown LCN count
Card general
Per card: Active (green), standby (yellow), fail (red)
Lines (one per): Active and okay (green)
Active and local alarm (red),
Active and remote alarm (yellow)
Internal problem isolation loopbacks
Hot-pluggable
FRSM-4E1: 7.25 in. x 16.25 in.
LM-DB15-4E1: 7.0 in. x 4.5 in.
LM-BNC-4E1: 7.0 in x 4.5 in.
–48V DC, 30W (4 E1s)
8000 cell buffer shared between virtual channels/paths
Standard usage parameter control (UPC)
Selective cell discard
Virtual circuit queuing
EFCI setting per VC
8000 cell storage capacity shared between four ports
Up to 12-user-selectable egress queues per port
Selective cell discard
EFCI setting per queue