FRSM-8E1 Specification

Statistics:
Diagnostics:

Card General

Indicators:
Maintenance/Serviceability
Features:
FRSM-8E1 Specification

Service Interface

Line Interface connector:
Line Rate:
Synchronization:
Input Jitter Tolerance:
Output Jitter Generation:
Physical Layer Alarms:
Number of Frame Interfaces:
Cisco MGX 8220 Installation and Configuration
B-20
Per Card:
Lines (one per):
Reliability:
Card Size:
All previous counters followed by an (S) can be configured as
statistics
Last unknown LCN received cells with unknown LCN count
Active (green), standby (yellow), fail (red)
Active and okay (green)
Active and local alarm (red)
Active and remote alarm (yellow)
Internal problem isolation loopbacks hot-pluggable
> 65000 hours MTBF
FRSM-8T1: 7.25 in. x 16.25 in.
LM-DB15-4T1: 7.0 in. x 4.5 in.
Power: –48V DC, 30W (8 T1s)
RJ-48 when used with LM-RJ-48-8E1 line module SMB when
used with LM-SMB-8E1 line module
2.048 Mbps 100 bps
Transmitter can be either loop-timed to receiver or
synchronized to shelf (called normal mode)
Per G.703
Per G.703
LOS, OOF, AIS, RAI
1 to 31 occupying n where 1 < n < 31. Sum of all < 31 for CCS
1–30 for CAS