Chapter 7
Troubleshooting the DPA 7630/7610
Table 7-6
Hardware Errors and Warnings Explanation
Error
Fan fault detected
Fault detected in
power supply
Resolving Network and System Errors
Table 7-7
Network and System Errors and Warnings Explanation
Error
IP address refused
IP address cannot
be allocated
Server address not
configured
78-11069-03
Explanation
The fan is not working
correctly.
The power supply is not
working correctly.
Table 7-7
describes errors and warnings that might appear on the DPA 7630/7610
either on-screen or in the event log, which are caused by a misconfiguration or
miscommunication with the network or system settings. Use this information to
resolve these errors.
Explanation
The DHCP server rejected
the DPA 7630/7610's
request for an IP address.
No DHCP server responded
to the request.
DHCP is not being used so
you must assign a static IP
address.
Cisco DPA 7630/7610 Voice Mail Gateways Administration Guide
Resolving Error and Warning Messages
Action
Turn off the DPA 7630/7610 and contact a
Cisco technical representative for assistance.
Immediately turn off the DPA 7630/7610 and
unplug it. Contact a Cisco technical
representative for assistance.
Action
Check configuration of DHCP server. If
errors persist, assign a static IP address. Refer
to
"Configuring Network Settings" section on
page 5-4
for details on assigning a static IP
address.
Check configuration of DHCP server. If
errors persist, assign a static IP address. Refer
to
"Configuring Network Settings" section on
page 5-4
for details on assigning a static IP
address.
Refer to
"Configuring Network Settings"
section on page 5-4
for details on assigning a
static IP address.
7-19