hit counter script

IBM x3250 M3 Problem Determination And Service Manual page 125

Hide thumbs Also See for x3250 M3:
Table of Contents

Advertisement

Table 6. DSA Preboot messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v See Chapter 4, "Parts listing, System x3250 M3 Types 4251, 4252, and 4261," on page 119 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a Trained
service technician.
v Go to the IBM support website at http://www.ibm.com/systems/support/ to check for technical information, hints, tips,
and new device drivers or to submit a request for information.
Message
number
Component
215-901-xxx
Optical Drive
215-902-xxx
Optical Drive
Test
State
Description
Aborted
Drive media is
v Verify
not detected.
Media
Installed
v Read/
Write Test
v Self-Test
Messages
and actions
apply to all
three tests.
Failed
Read
v Verify
miscompare.
Media
Installed
v Read/
Write Test
v Self-Test
Messages
and actions
apply to all
three tests.
Action
1. Insert a CD/DVD into the drive or try a new
media, and wait for 15 seconds.
2. Run the test again.
3. Check the drive cabling at both ends for loose or
broken connections or damage to the cable.
Replace the cable if it is damaged.
4. Run the test again.
5. For additional troubleshooting information, go to
http://www.ibm.com/support/
docview.wss?uid=psg1MIGR-41559.
6. Run the test again.
7. Replace the CD/DVD drive.
8. If the failure remains, go to the IBM website for
more troubleshooting information at
http://www.ibm.com/systems/support/
supportsite.wss/docdisplay?brandind=5000008
&lndocid=SERV-CALL.
1. Insert a CD/DVD into the drive or try a new
media, and wait for 15 seconds.
2. Run the test again.
3. Check the drive cabling at both ends for loose or
broken connections or damage to the cable.
Replace the cable if it is damaged.
4. Run the test again.
5. For additional troubleshooting information, go to
http://www.ibm.com/support/
docview.wss?uid=psg1MIGR-41559.
6. Run the test again.
7. Replace the CD/DVD drive.
8. If the failure remains, go to the IBM website for
more troubleshooting information at
http://www.ibm.com/systems/support/
supportsite.wss/docdisplay?brandind=5000008
&lndocid=SERV-CALL.
Chapter 3. Diagnostics
107

Advertisement

Table of Contents
loading

Table of Contents