Mode selections for the Axis of Motion
Two-Speed, Continuous Rotation, with triggered stop
Creating the steps of the profile
You specify the target speed and ending position or number of pulses for each step.
Additional steps are entered one at a time. The figure illustrates a one-step, two-step, three-
step, and a four-step profile.
Notice that a one-step profile has one constant speed segment, a two-step profile has two
constant speed segments, and so on. The number of steps in the profile matches the
number of constant speed segments of the profile.
S7-200 SMART
System Manual, V2.3, 07/2017, A5E03822230-AF
Open loop motion control
12.2 Using motion control
A step is a fixed distance that a tool
moves, including the distance covered
during acceleration and deceleration
times. The Axis of Motion supports a max-
imum of 16 steps in each profile.