hit counter script

System Health Module - Cisco AJ732A - MDS 9134 Fabric Switch Command Reference Manual

Cisco mds 9000 family command reference guide - release 4.x (ol-18089-01, february 2009)
Hide thumbs Also See for AJ732A - Cisco MDS 9134 Fabric Switch:
Table of Contents

Advertisement

Chapter 21
S Commands
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m

system health module

To configure Online Health Management System (OHMS) features for a specified module, use the
system health module command. To disable these features, use the no form of this command.
Syntax Description
module slot
battery-charger
frequency seconds
failure-action
bootflash
cache-disk
cf-crc-check
cf-re-flash
eobc
inband
loopback
mgmt
OL-18089-01, Cisco MDS NX-OS Release 4.x
system health module slot
[battery-charger [failure-action | frequency seconds] |
bootflash [failure-action | frequency seconds] |
cache-disk [failure-action | frequency seconds] |
cf-crc-check [failure-action | frequency frequency] |
cf-re-flash [failure-action | frequency frequency] |
eobc [failure-action | frequency seconds] |
failure-action |
inband [failure-action | frequency seconds] |
loopback [failure-action] |
mgmt [failure-action | frequency seconds]]
no system health module slot
[battery-charger [failure-action | frequency seconds] |
bootflash [failure-action | frequency seconds] |
cache-disk [failure-action | frequency seconds] |
cf-crc-check [failure-action | frequency frequency] |
cf-re-flash [failure-action | frequency frequency] |
eobc [failure-action | frequency seconds] |
failure-action |
inband [failure-action | frequency seconds] |
loopback [failure-action] |
mgmt [failure-action | frequency seconds]]
Specifies the module slot number.
Configures the battery-charger test on the specified module.
Specifies the frequency in seconds. The range for the bootflash
frequency option is 10 to 255. The range for the cf-crc-check frequency
option is 1 to 30. The range for the cf-re-flash frequency option is 30 to
90. For all other options, the range is 5 to 255.
Controls the software from taking any action if a CompactFlash failure is
determined while running the CRC checksum test.
Configures the bootflash test on the specified module.
Configures the cache-disk test on the specified module.
Configures the CRC checksum test.
Configures the firmware update.
Configures the EOBC test on the specified module.
Configures the inband test on the specified module.
Configures the loopback test on the specified module.
Configures the management port test on the specified module.
Cisco MDS 9000 Family Command Reference
system health module
21-117

Advertisement

Table of Contents
loading

Table of Contents