Activate the new zone configuration.
Step 11
switch(config)# zoneset activate name zs1 vsan 2
Zoneset activation initiated. check zone status
switch(config)# exit
Display the active zoneset to ensure the data in the new zone configuration is correct. Also confirm that
Step 12
the pWWNs are correct.
switch# show zoneset active vsan 2
zoneset name zs1 vsan 2
zone name zzz1 vsan 2
* fcid 0x211324 [pwwn 50:00:53:00:01:c9:70:01] [vdev1]
switch# show sdv database vsan 2
sdv virtual-device name vdev1 vsan 2
[ WWN:50:00:53:00:00:d2:e0:01 FCID:0x960001 Real-FCID:0x9f0201 ]
virtual-fcid 0x960001
* pwwn 21:00:00:04:cf:cf:45:40 primary
pwwn 21:00:00:04:cf:cf:38:d6
Enter the SDV manager configuration submode and display the pWWNs for the virtual devices in vsan
Step 13
2. After making a note of the pWWNs, migrate the primary virtual device to the secondary device, link
this new primary device to a physical device, and then commit this configuration to the fabric. Confirm
that the secondary virtual device is now the primary.
switch# conf t
switch(config-sdv-virt-dev)# link pwwn 21:00:00:04:cf:cf:38:d6
switch(config-sdv-virt-dev)# exit
switch(config)# sdv commit vsan 2
switch(config)# do show sdv database vsan 2
sdv virtual-device name vdev1 vsan 2
[ WWN:50:00:53:00:00:d2:e0:01 FCID:0x960001 Real-FCID:0x9f0423 ]
virtual-fcid 0x960001
pwwn 21:00:00:04:cf:cf:45:40
* pwwn 21:00:00:04:cf:cf:38:d6 primary
virtual-device name vdev2 vsan 2
[ WWN:50:00:53:00:00:0b:50:01 ]
Displaying SDV Information
To display the results of the last commit to the SDV database, enter this command:
switch# show sdv session status vsan
Session Parameters for VSAN: 1
-------------------------------
Last Action Time Stamp
Last Action
Last Action Result
Last Action Failure Reason : none
Cisco MDS 9000 Family CLI Configuration Guide
21-16
pwwn 50:00:53:00:01:c9:70:01 [vdev1]
pwwn 21:00:03:04:55:cf:d6:40
pwwn 21:00:03:04:55:cf:d6:40
1
: Fri Feb
2 10:17:20 2007
: Commit
: Success