Chapter 1
Configuring IP Unicast Routing
Command
Step 6
standby 1 ip ip-address
Step 7
end
User Interface for uRPF
uRPF can be configured on an interface assigned to a VRF, and source lookup is done in the VRF table.
Beginning in privileged EXEC mode, follow these steps to configure VRF-aware services for uRPF. For
complete syntax and usage information for the commands, refer to the switch command reference for
this release and the Cisco IOS Switching Services Command Reference, Release 12.4.
Command
Step 1
configure terminal
Step 2
interface interface-id
Step 3
no switchport
Step 4
ip vrf forwarding vrf-name
Step 5
ip address ip-address
Step 6
ip verify unicast reverse-path
Step 7
end
User Interface for VRF-Aware RADIUS
To configure VRF-Aware RADIUS, you must first enable AAA on a RADIUS server. The switch
supports the ip vrf forwarding vrf-name server-group configuration and the ip radius source-interface
global configuration commands, as described in the Per VRF AAA Feature Guide:
http://www.cisco.com/en/US/docs/ios/12_2t/12_2t13/feature/guide/ftvrfaaa.html
User Interface for Syslog
Beginning in privileged EXEC mode, follow these steps to configure VRF-aware services for Syslog.
For complete syntax and usage information for the commands, refer to the switch command reference
for this release and the Cisco IOS Switching Services Command Reference, Release 12.4.
Command
Step 1
configure terminal
Step 2
logging on
Step 3
logging host ip-address vrf vrf-name
Step 4
logging buffered logging buffered size
debugging
Step 5
logging trap debugging
OL-25303-03
Purpose
Enable HSRP and configure the virtual IP address.
Return to privileged EXEC mode.
Purpose
Enter global configuration mode.
Enter interface configuration mode, and specify the Layer 3 interface to
configure.
Remove the interface from Layer 2 configuration mode if it is a physical
interface.
Configure VRF on the interface.
Enter the IP address for the interface.
Enable uRPF on the interface.
Return to privileged EXEC mode.
Purpose
Enter global configuration mode.
Enable or temporarily disable logging of storage router event message.
Specify the host address of the syslog server where logging messages
are to be sent.
Log messages to an internal buffer.
Limit the logging messages sent to the syslog server.
Catalyst 3750-X and 3560-X Switch Software Configuration Guide
Configuring Multi-VRF CE