Configuring Alarm Profiles - Cisco IE 3000 Software Configuration Manual

Table of Contents

Advertisement

Chapter 3
Configuring Cisco IE 3000 Switch Alarms
This example shows how to set the FCS bit error rate for a port to 10
Switch# configure terminal
Switch(config)# interface fastethernet1/1
Switch(config-if) # fcs-threshold 10
Setting the FCS Error Hysteresis Threshold
The hysteresis setting prevents the toggle of an alarm when the actual bit error-rate fluctuates near the
configured rate. Use the alarm facility fcs-hysteresis global configuration command to set the FCS
error hysteresis threshold.
The FCS hysteresis threshold is applied to all ports of an IE 3000 switch.
Note
Beginning in privileged EXEC mode, follow these steps to set the FCS error hysteresis threshold for a
switch:
Command
Step 1
configure terminal
Step 2
alarm facility fcs-hysteresis
percentage
Step 3
end
Step 4
show running config
Step 5
copy running-config startup-config (Optional) Save your entries in the configuration file.
Use the no alarm facility fcs-hysteresis command to set the FCS error hysteresis threshold to its default
value.
The show running config command displays any FCS error hysteresis that is not the default value.
Note
This example shows how to set the FCS error hysteresis at 5 percent.
Switch(config)# alarm facility fcs-hysteresis 5

Configuring Alarm Profiles

This section describes how to configure alarm profiles on your switch. It contains this configuration
information:
OL-13018-01
Purpose
Enter global configuration mode.
Set the hysteresis percentage for the switch.
For percentage, the range is 1 to 10. The default value is 10 percent.
Return to privileged EXEC mode.
Verify the configuration.
Creating or Modifying an Alarm Profile, page 3-10
Attaching an Alarm Profile to a Specific Port, page 3-11
Configuring IE 3000 Switch Alarms
-10
.
Cisco IE 3000 Switch Software Configuration Guide
3-9